Line 504: Line 504:


'''Fine Offset stations''' are prone to reporting the odd nonsensical value, and Cumulus has the ability to compare successive readings:
'''Fine Offset stations''' are prone to reporting the odd nonsensical value, and Cumulus has the ability to compare successive readings:
*From the '''Configuration''' menu select [[Cumulus_Screenshots#Configuration_Menu_Screens|''Calibration'']] and in the '''Spike removal''' frame you can specify "the maximum '''differences''' between successive values" that Cumulus is to tolerate. See the '''Help''' for that screen, and note that spike removal applies while Cumulus is running, not to catch-up readings from the station's logger.  
*{{Version badge 1}}From the '''Configuration''' menu select [[Cumulus_Screenshots#Configuration_Menu_Screens|''Calibration'']] and in the '''Spike removal''' frame you can specify "the maximum '''differences''' between successive values" that Cumulus is to tolerate.  
*{{Version badge 1}}See the '''Help''' for that screen, and note that '''spike removal applies while Cumulus is running''', it is not applied to catch-up readings from the station's logger.  


'''Possible Cure:'''
'''Possible Cure:'''
Line 544: Line 545:
Because many positive values are realistic, Cumulus generally will accept those odd increases as a result of accidental knocking of a tipping bucket gauge, due to wind effects on the gauge, or even due to the station electronics generating a rogue reading. The sub-answers below explain how to correct such errors.
Because many positive values are realistic, Cumulus generally will accept those odd increases as a result of accidental knocking of a tipping bucket gauge, due to wind effects on the gauge, or even due to the station electronics generating a rogue reading. The sub-answers below explain how to correct such errors.
=== (Invented rain) Error in today's total ===
=== (Invented rain) Error in today's total ===
Easy - correct today's total using the [[Today.ini#Editing_rainfall_in_today.ini_within_Cumulus | 'today's rain']] editor on the edit menu (select from main screen in Cumulus 1, or find in the MX browser interface).
Easy - correct today's total using the [[Today.ini#Editing_rainfall_in_today.ini_within_Cumulus | 'today's rain']] editor on the edit menu (select from main screen in Cumulus 1, or find in the MX admin interface).


=== (Invented rain) Error in date/time of 'Last Tip' ===
=== (Invented rain) Error in date/time of 'Last Tip' ===
Line 628: Line 629:
If you do this, you will probably need to edit your log files in the '''data''' folder as you may have duplicate entries and/or entries out of order. Your rain totals will almost certainly also be wrong - the total for "today" in particular. See the [[FAQ#My_station_invented_some_rain_that_didn.27t_really_occur.2C_and_I_want_to_set_it_to_zero_.28or_some_other_figure.29 |FAQ]] entry about correcting rainfall data. If you have only just started using Cumulus, you could delete all of the files in the data folder, and just create a simple today.ini as below. Then when you start Cumulus, processing will start again with just the data from the station's logger.
If you do this, you will probably need to edit your log files in the '''data''' folder as you may have duplicate entries and/or entries out of order. Your rain totals will almost certainly also be wrong - the total for "today" in particular. See the [[FAQ#My_station_invented_some_rain_that_didn.27t_really_occur.2C_and_I_want_to_set_it_to_zero_.28or_some_other_figure.29 |FAQ]] entry about correcting rainfall data. If you have only just started using Cumulus, you could delete all of the files in the data folder, and just create a simple today.ini as below. Then when you start Cumulus, processing will start again with just the data from the station's logger.


Note that this method does not work for the Oregon WMR200 station. This station deletes logger entries when they are downloaded, and there is no mechanism for retrieving logger entries for a particular period - it just sends all the entries that it has. You may be able to circumvent this by creating a today.ini file in the data folder before you run Cumulus 1, with just this in it:
Note that this method does not work for the Oregon WMR200 station. This station deletes logger entries when they are downloaded, and there is no mechanism for retrieving logger entries for a particular period - it just sends all the entries that it has. {{Version badge 1}}You may be able to circumvent this by creating a today.ini file in the data folder before you run Cumulus 1, with just this in it:
<pre>
<pre>
[General]
[General]
Line 637: Line 638:
CurrentDay=10
CurrentDay=10
</pre>
</pre>
Note that Cumulus MX stores some time-stamps '''in ISO format''' (yyyy/MM/dd HH:mm:ss) within '[[today.ini]]', the format example above only works for Cumulus 1, see the article on the log file itself for specifics.
Note that Cumulus MX stores some time-stamps '''in ISO format''' (yyyy/MM/dd HH:mm:ss) within '[[today.ini]]', the format example above only works for {{Version badge 1}}Cumulus 1, see the article on the log file itself for specifics.
Change the dates and time to match the point from which you want Cumulus to start downloading data. If the station has already sent the data, this may not work, unfortunately.
Change the dates and time to match the point from which you want Cumulus to start downloading data. If the station has already sent the data, this may not work, unfortunately.


Line 652: Line 653:
{{Version badge 1}}'''Note''' ''StartDate=xxxx'' does ''not'' need to be updated for Cumulus 1 to recognise earlier data in log files in its ''data'' subfolder.   
{{Version badge 1}}'''Note''' ''StartDate=xxxx'' does ''not'' need to be updated for Cumulus 1 to recognise earlier data in log files in its ''data'' subfolder.   


[[File:Badge vMx.png]] However in calculating and updating extremes, Cumulus MX will ignore any monthly log file data prior to the start date set, so it is crucial to make sure the start date is right before you (re-)start MX.
[[File:Badge vMx.png]] However in calculating and updating extremes, '''CumulusMX.exe''' will ignore any standard log file for any month prior to the start date set, so it is crucial to make sure the start date is right before you (re-)start MX. However, if you use '''ExportMySQL.exe monthly''' this will start with January 2000 and process any standard log found for any month after that.


{{Version badge 1}}It really represents "Cumulus began on", so there is an alternative of leaving cumulus.ini unchanged, but editing default Cumulus ''recordsT.htm'' template twice:
{{Version badge 1}}and [[File:Badge vMx.png]]There is one web page template file ''recordT.htm'' that in two places uses this date. If you want to make one of those be the earliest date you  now have for your data and the other one to be when you started using Cumulus; there is an alternative of leaving '''Cumulus.ini''' unchanged, but editing the ''recordT.htm'' template twice:
*after the h2 heading is ''&lt;p&gt;Records began on <#recordsbegandate>. Here are the extremes recorded since then.&lt;/p&gt;'';  you can replace '<#recordsbegandate>' with the new earliest date typed in as text; and