Cumulus.ini (preserving history): Difference between revisions

m
→‎Davis family specific:: Some consistency changes (mention whether read-only or read-write)
m (→‎Davis family specific:: Some consistency changes (mention whether read-only or read-write))
Line 992: Line 992:
*1 = Enabled (default)
*1 = Enabled (default)
|-
|-
|colspan="2" style="background:lightblue;"| Both Cumulus flavours - in MX edit in Station Settings,  for Cumulus 1 edit in Station Configuration Screen
|colspan="2" style="background:lightblue;"| Read-write parameters: Both Cumulus flavours - in MX edit in Station Settings,  for Cumulus 1 edit in Station Configuration Screen
|-
|-
|ForceVPBarUpdate=0  
|ForceVPBarUpdate=0  
Line 1,034: Line 1,034:
|This is set in the '''Settings''' block on the Station settings screen off the configuration menu. Set this to 1 if you have additional sensors (e.g. a Davis Leaf Wetness probe) to make Cumulus read, display, and log the readings from the sensors. You don't select this for Solar/UV sensors.
|This is set in the '''Settings''' block on the Station settings screen off the configuration menu. Set this to 1 if you have additional sensors (e.g. a Davis Leaf Wetness probe) to make Cumulus read, display, and log the readings from the sensors. You don't select this for Solar/UV sensors.
|-
|-
|colspan="2" style="background:lightblue;"|{{Version badge 1}}  Cumulus 1 only: edit in Station Configuration Screen or file as indicated
|colspan="2" style="background:lightblue;"|{{Version badge 1}}  Cumulus 1 only: edit in Station Configuration Screen (if read-write) or file (both read-only and read-write) as indicated
|-
|-
|DavisRainCollectorModel=X
|DavisRainCollectorModel=X
Line 1,061: Line 1,061:
Identifies COM Port used if Davis type is serial. Default is 0.
Identifies COM Port used if Davis type is serial. Default is 0.
|-
|-
|colspan="2" style="background:lightblue;"| Only available in Cumulus MX: edit in Station Settings or if read-only directly in file
|colspan="2" style="background:lightblue;"| Only available in Cumulus MX: edit in Station Settings (if read-write) or if read-only directly in file
|-
|-
|UseDavisLoop2=1
|UseDavisLoop2=1
Line 1,083: Line 1,083:
|-
|-
|DavisIncrementPressureDP=0
|DavisIncrementPressureDP=0
|[[File:Badge vMx.png]](from version 3.0.0 build 3042) A Cumulus.ini setting to turn off the 'extra' decimal place in pressure values on Davis stations. To limit the pressure to 1 decimal for mb/hPa and 2 for inHg, add this to the [Station] section
|[[File:Badge vMx.png]](from version 3.0.0 build 3042) A read-only Cumulus.ini setting to turn off the 'extra' decimal place in pressure values on Davis stations. To limit the pressure to 1 decimal for mb/hPa and 2 for inHg, add this to the [Station] section
|-
|-
|VPrainGaugeType=0
|VPrainGaugeType=0
Line 1,093: Line 1,093:
|-
|-
|DataLogging=0
|DataLogging=0
|[[File:Badge vMx.png]]Set in options section of station settings page. Default is 0, change to 1 for more detailed Davis logging.
|[[File:Badge vMx.png]]Read-write: Set in options section of station settings page. Default is 0, change to 1 for more detailed Davis logging.
   
   
*0 (default) = Cumulus MX will not add extra logging.
*0 (default) = Cumulus MX will not add extra logging.
Line 1,103: Line 1,103:
|-
|-
|ZeroConfig
|ZeroConfig
|[[File:Badge vMx.png]]set this on station settings screen; to enable/disable the entry/update of the stations IP address via auto-discovery
|[[File:Badge vMx.png]]Read-write: set this on station settings screen; to enable/disable the entry/update of the stations IP address via auto-discovery
|}
|}


5,838