Cumulus.ini (preserving history): Difference between revisions

m
→‎Spike Removal: correcting layout
m (→‎Spike Removal: correcting layout)
Line 1,180: Line 1,180:
|Add this line to cumulus.ini [Station] section
|Add this line to cumulus.ini [Station] section
Cumulus (1 and MX) has a configurable threshold for the maximum feasible amount of rain between updates (i.e. within 48-seconds on Fine Offset stations without solar, 60 seconds on those measuring solar), set in units of count of tips.
Cumulus (1 and MX) has a configurable threshold for the maximum feasible amount of rain between updates (i.e. within 48-seconds on Fine Offset stations without solar, 60 seconds on those measuring solar), set in units of count of tips.
Default=30 tips, as each tip represents 0.3mm this is equivalent to 9 mm or just over a third of an inch in 48 seconds.
Default=30 tips, as each tip represents 0.3mm this is equivalent to 9 mm or just over a third of an inch in 48 seconds.
This setting affects rain rate, rain last hour, rain so far today (and what is recorded in today.ini/dayfile.txt), but does not affect the web tag <#r24hour>.
This setting affects rain rate, rain last hour, rain so far today (and what is recorded in today.ini/dayfile.txt), but does not affect the web tag <#r24hour>.
|-
|-
Line 1,192: Line 1,194:
|EWmaxRainRate=999
|EWmaxRainRate=999
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu.
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu.
A rain rate 'spike removal' filter, ''changes in calculated value'', between one calculation and the next, greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus when it calculates the rain rate.
A rain rate 'spike removal' filter, ''changes in calculated value'', between one calculation and the next, greater than the value specified here (set in calibration screen of configuration menu) will be ignored by Cumulus when it calculates the rain rate.
Cumulus ignores this parameter for other makes of weather station (they supply a rain rate to Cumulus). The default value of '''999''' also effectively makes Cumulus ignore spike removal.
Cumulus ignores this parameter for other makes of weather station (they supply a rain rate to Cumulus). The default value of '''999''' also effectively makes Cumulus ignore spike removal.


|-
|-
|EWgustdiff=999.0
|EWgustdiff=999.0
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu. A wind gust 'spike removal' filter, ''changes in calculated value'' between one calculation and the next, greater than the value (always metres per second) specified here (with a default of '''999.0''') will be ignored by Cumulus.
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu.  
 
A wind gust 'spike removal' filter, ''changes in calculated value'' between one calculation and the next, greater than the value (always metres per second) specified here (with a default of '''999.0''') will be ignored by Cumulus.


|-
|-
|EWwinddiff=999.0
|EWwinddiff=999.0
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu.. A wind speed  'spike removal' filter, ''changes in calculated value'' between one calculation and the next greater than the value (always metres per second) specified here (with a default of '''999.0''') will be ignored by Cumulus
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu.
 
A wind speed  'spike removal' filter, ''changes in calculated value'' between one calculation and the next greater than the value (always metres per second) specified here (with a default of '''999.0''') will be ignored by Cumulus


|-
|-
Line 1,210: Line 1,218:
|EWminpressureMB=900
|EWminpressureMB=900
|Add this line to cumulus.ini [Station] section
|Add this line to cumulus.ini [Station] section
Cumulus will ignore all pressure readings from the station that are less than this value (units are always hPa/millibars)
Cumulus will ignore all pressure readings from the station that are less than this value (units are always hPa/millibars)


Line 1,215: Line 1,224:
|EWmaxpressureMB=1200
|EWmaxpressureMB=1200
|Add this line to cumulus.ini [Station] section
|Add this line to cumulus.ini [Station] section
Cumulus will ignore all pressure readings from the station that are greater than this value (units are always hPa/millibars).
Cumulus will ignore all pressure readings from the station that are greater than this value (units are always hPa/millibars).


Line 1,224: Line 1,234:
|-
|-
|EWhumiditydiff=999.0
|EWhumiditydiff=999.0
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu. A humidity change 'spike removal' filter, ''changes in read value'' from any station greater than the value (as %) specified here (with a default of '''999.0''') will be ignored by Cumulus.
|This is set in the spike removal frame on the Calibration settings screen off the configuration menu.  
 
A humidity change 'spike removal' filter, ''changes in read value'' from any station greater than the value (as %) specified here (with a default of '''999.0''') will be ignored by Cumulus.


|-
|-
5,838