Cumulus.ini (preserving history): Difference between revisions

From Cumulus Wiki
Jump to navigationJump to search
m
m (→‎Section: Solar: Merged the two separate table into a single table, instead of separate table for MX only parameters)
(2 intermediate revisions by the same user not shown)
Line 1,374: Line 1,374:
|colspan="2" style="background:pink;"|Read-only parameters - The parameter listed below must be entered directly into file with Cumulus stopped. Used in both C1 and MX.
|colspan="2" style="background:pink;"|Read-only parameters - The parameter listed below must be entered directly into file with Cumulus stopped. Used in both C1 and MX.
|-
|-
|TempMult2=0.0  
|TempMult2=1.0  
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default second order multiplier is 1.0.
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default second order multiplier is 1.0.
"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 X measured-temp X measured_temp) + (TempMult X measured_temp) + TempOffset
"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 X measured-temp X measured_temp) + (TempMult X measured_temp) + TempOffset
|-
|colspan="2" style="background:pink;"|Read-only parameters - The parameter listed below must be entered directly into file with Cumulus stopped. Only MX (build 3045 onwards).
|-
|HumMult2=1.0
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default second order multiplier is 1.0.
"Second order" multiplier by which measured outdoor Humidity is to be corrected, this means that the logged reading can be (HumMult2 X measured_hum X measured_hum) + (HumMult X measured_hum) + HumOffset
|-
|-
|colspan="3" style="background:lightblue;"| Both Cumulus flavours
|colspan="3" style="background:lightblue;"| Both Cumulus flavours
|-
|-
|TempOffset=Offset_Value  
|TempOffset=Offset_Value  
|Default 'Offset_Value' is 0 in this parameter, used for quadratic formula shown below
|Default 'Offset_Value' is 0 in this parameter, used for quadratic formula shown for read-only parameter
|-
|-
|TempMult=1  
|TempMult=1  
Line 1,388: Line 1,394:
|-
|-
|HumMult=1  
|HumMult=1  
|Multiplier by which measured Humidity is to be corrected (default=1). See formula in next row
|Multiplier by which measured Humidity is to be corrected (default=1). See formula in read-only parameter
|-
|-
|HumOffset=Offset_Value  
|HumOffset=Offset_Value  
|Default 'Offset_Value' is 0 in this parameter used for formula: Cumulus Humidity = measured_Humidity X Humidity_multiplier + 'Offset_Value'
|Default 'Offset_Value' is 0 in this parameter used for formula in MX read-only parameter above
|-
|-
|WetBulbMult=1
|WetBulbMult=1
Line 1,483: Line 1,489:
|-
|-
|colspan="2" style="background:lightblue;"| Both Cumulus flavours - in MX edit in Internet Settings, see individual entry for Cumulus 1 edits
|colspan="2" style="background:lightblue;"| Both Cumulus flavours - in MX edit in Internet Settings, see individual entry for Cumulus 1 edits
|-
|Logging=0
|Determines whether enhanced "debugging" logging takes place where Cumulus 1 or MX makes a detailed record of each action that takes place.
*0 (default) = Cumulus 1 or MX will not add debug logging.
*1 = For '''debug''' logging when Cumulus 1 or MX (re-)starts, add ''Logging=1'' to the station section of Cumulus.ini while Cumulus is stopped.
[[File:Badge vMx.png]] In MX only, it can also be set in the admin interface internet settings screen. Note that if set on the admin interface, it only remains set while Cumulus continues to run, and resets to default off when MX re-starts. For MX, if you want debugging output every time it runs, then add "-debug" parameter as explained at [[Cumulus_MX#Parameter_for_adding_debugging|Parameter_for_adding_debugging]]
|-
|-
|DailyProgram=  
|DailyProgram=  
5,838

edits

Navigation menu