Cumulus.ini (preserving history): Difference between revisions

m
Line 1,331: Line 1,331:
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration.
|-
|-
|colspan="2" style="background:lightblue;"| Both Cumulus flavours - in MX edit in Station Settings,  for Cumulus 1 edit in Station Configuration Screen
|colspan="2" style="background:pink;"|Read-only parameters - The parameters listed below must be entered directly into file with Cumulus stopped. Used in both C1 and MX unless indicated.
|-
|-
|ImetWaitTime=200
|ImetWaitTime=200
|This parameter (attribute=value) if you need to change it from its '''default of 200 ms''' is added directly to the file, it does not appear on a configuration screen.  
|This parameter (attribute=value) if you need to change it from its '''default of 200 ms''' is added directly to the file, it does not appear on a configuration screen.  
Specifies the time in milliseconds that Cumulus allows for a response from an Instromet station. If you are having problems with reading from an Instromet station, try inserting this line into the ''Station'' section using a value of 500. According to the specification, 500 ms is the absolute maximum time that the station should take to respond to any command.
Specifies the time in milliseconds that Cumulus allows for a response from an Instromet station. If you are having problems with reading from an Instromet station, try inserting this line into the ''Station'' section using a value of 500. According to the specification, 500 ms is the absolute maximum time that the station should take to respond to any command.
|-
|colspan="2" style="background:pink;"| Only Cumulus MX: Read-only
|-
|ImetBaudRate=19200
|This parameter (attribute=value) is added directly to the file, it does not appear on a configuration screen.
The default value is 19200. Some ?older? Instromet loggers operate at 115200, if you have one of these older loggers you will need to manually set this value in Cumulus.ini before running the program.
|-
|colspan="2" style="background:lightblue;"| Both Cumulus flavours - in MX edit in Station Settings,  for Cumulus 1 edit in Station Configuration Screen
|-
|-
|SyncDavisClock=0  
|SyncDavisClock=0  
Line 1,348: Line 1,356:
*1= Enabled - Used for optional Sunshine hours or extra temperature sensors on Instromet stations. For a wet bulb sensor, Cumulus will output the temperature it shows, but not calculate the humidity.
*1= Enabled - Used for optional Sunshine hours or extra temperature sensors on Instromet stations. For a wet bulb sensor, Cumulus will output the temperature it shows, but not calculate the humidity.
(Note this attribute appears in [[#Davis_family_specific|Davis family]], [[#Oregon_Scientific_specific:|Oregon Scientific specific]] and [[#Introduced_for_problems_with_Fine_Offset_family:|Fine Offset family]] tables above with different usage explanations).
(Note this attribute appears in [[#Davis_family_specific|Davis family]], [[#Oregon_Scientific_specific:|Oregon Scientific specific]] and [[#Introduced_for_problems_with_Fine_Offset_family:|Fine Offset family]] tables above with different usage explanations).
|-
|colspan="2" style="background:lightblue;"| Only Cumulus MX: edit in Station Settings
|-
|ImetBaudRate=19200
|This parameter (attribute=value) is added directly to the file, it does not appear on a configuration screen.
The default value is 19200. Some ?older? Instromet loggers operate at 115200, if you have one of these older loggers you will need to manually set this value in Cumulus.ini before running the program.
|}
|}


5,838

edits