5,838
edits
m (→Instromet specific:: new sub-section - see forum /viewtopic.php?f=4&t=12423) |
|||
Line 546: | Line 546: | ||
==== Hydreon specific: ==== | ==== Hydreon specific: ==== | ||
All 6 of these parameters are set on RG11 screen within configuration menu, see its ''Help'' for more information. | |||
{| class="wikitable" border="1" | {| class="wikitable" border="1" | ||
|- | |- | ||
Line 555: | Line 556: | ||
|- | |- | ||
|RG11port=1 | |RG11port=1 | ||
|Specifies the COM port to use for [[Rain_measurement#Optical_Rain_Gauge | Hydreon RG-11 rain detection devices]]. 1 = COM1 | |Specifies the COM port to use for [[Rain_measurement#Optical_Rain_Gauge | Hydreon RG-11 rain detection devices]]. 1 = COM1. | ||
|- | |- | ||
|RG11TBRmode=1 | |RG11TBRmode=1 | ||
|Specifies the Hydreon RG-11 rain device mode of operation. | |Specifies the Hydreon RG-11 rain device mode of operation. | ||
*0 = Rain detection mode - "It's Raining" | *0 = Rain detection mode - "It's Raining" | ||
*1 = Tipping bucket mode | *1 = Tipping bucket mode. | ||
|- | |- | ||
|RG11tipsize=0.01 | |RG11tipsize=0.01 | ||
|Specifies the tipping bucket size for Hydreon RG-11 rain detection devices. The 'tip size' must be specified in the units that you have configured Cumulus to use for rain | |Specifies the tipping bucket size for Hydreon RG-11 rain detection devices. The 'tip size' must be specified in the units that you have configured Cumulus to use for rain. | ||
|- | |- | ||
|RG11port2= | |RG11port2= | ||
Line 570: | Line 571: | ||
RG11tipsize2= | RG11tipsize2= | ||
|Settings to connect a second Hydreon RG-11 rain detection device | |Settings to connect a second Hydreon RG-11 rain detection device. | ||
Note that you must have one RG-11 set to "It's raining" mode and the other to "tipping bucket" mode. Cumulus does not validate this. | Note that you must have one RG-11 set to "It's raining" mode and the other to "tipping bucket" mode. Cumulus does not validate this. | ||
|} | |||
==== Instromet station specific: ==== | |||
{| class="wikitable" border="1" | |||
|- | |||
!style="width:150px" | Parameter Line Entry | |||
!style="width:600px" | Function | |||
|- | |||
|style="background:lightgray;"|[Station] | |||
|style="background:lightgray;"|Section name - the following parameters relate to the station configuration. | |||
|- | |||
|ImetWaitTime=200 | |||
|This parameter (attribute=value) if you need to change it from its '''default of 200 ms''' is added directly to the file, it does not appear on a configuration screen. | |||
Specifies the time in milliseconds that Cumulus allows for a response from an Instromet station. If you are having problems with reading from an Instromet station, try inserting this line into the ''Station'' section using a value of 500. According to the specification, 500 ms is the absolute maximum time that the station should take to respond to any command. | |||
|- | |||
|SyncDavisClock=0 | |||
|Set this in the Station Configuration Screen Settings block where called '''Synchronize station clock'''. Note despite the name of the parameter within 'Cumulus.ini', this does apply to Instromet stations. | |||
When set, at Cumulus start-up and at 04:00 each day, Cumulus will set the Davis VP/VP2 clock to within a minute of the same time as the PC | |||
*0 = Disabled, default as deselected on the Station Configuration Screen | |||
*1 = Enabled, ensures that when Cumulus asks the station for data since time X, both recognise X! | |||
|- | |||
|LogExtraSensors=0 | |||
|This is set in the settings frame on the Station settings screen off the configuration menu by the '''Extra Sensors''' selection. | |||
*0=Disabled (default) | |||
*1= Enabled - Used for optional Sunshine hours or extra temperature sensors on Instromet stations. | |||
(Note this attribute appears in [[#Davis_family_specific|Davis family]], [[#Oregon_Scientific_specific:|Oregon Scientific specific]] and [[#Introduced_for_problems_with_Fine_Offset_family:|Fine Offset family]] tables above with different usage explanations). | |||
|} | |} | ||
edits