5,838
edits
Line 573: | Line 573: | ||
== Section: Offsets == | == Section: Offsets == | ||
Set these parameters using the '''Configuration''' menu and ''Calibration'' screen, | Set most of these parameters using the '''Configuration''' menu and ''Calibration'' screen, the exception is 'TempMult2'. | ||
{| class="wikitable" border="1" | {| class="wikitable" border="1" | ||
|- | |- | ||
Line 583: | Line 583: | ||
|- | |- | ||
|PressOffset=Offset_Value | |PressOffset=Offset_Value | ||
|Default 'Offset_Value' is 0 in this parameter used for formula: Cumulus pressure = Measured Pressure + 'Offset_Value' | |Default 'Offset_Value' is 0 in this parameter, used for formula: Cumulus pressure = Measured Pressure + 'Offset_Value' | ||
|- | |- | ||
|TempOffset=Offset_Value | |TempOffset=Offset_Value | ||
|Default 'Offset_Value' is 0 in this parameter used for formula | |Default 'Offset_Value' is 0 in this parameter, used for quadratic formula shown below | ||
|- | |||
|TempMult=1 | |||
|First order multiplier by which measured outdoor Temperature is to be corrected (default=1). | |||
For formula see next item. | |||
|- | |||
|TempMult2= multiplier | |||
|This line needs to be added in the [Offsets] section of the Cumulus.ini, if it is omitted default multiplier is 1.0. | |||
"Second order" multiplier by which measured outdoor Temperature is to be corrected, this means that the logged reading can be (TempMult2 * measured-temp * measured_temp) + (TempMult * measured_temp) + TempOffset | |||
|- | |- | ||
|HumOffset=Offset_Value | |HumOffset=Offset_Value | ||
Line 604: | Line 612: | ||
|WindGustMult=1 | |WindGustMult=1 | ||
|Multiplier by which measured [[Wind_measurement#Wind_Speed|Wind Gust]] Speed is to be corrected (default=1). | |Multiplier by which measured [[Wind_measurement#Wind_Speed|Wind Gust]] Speed is to be corrected (default=1). | ||
|- | |- | ||
|HumMult=1 | |HumMult=1 |
edits