Cumulus.ini (preserving history): Difference between revisions

m
→‎Section: Display: Tidying order
m (→‎Section: Display: add 'Display solar/extra data')
m (→‎Section: Display: Tidying order)
Line 786: Line 786:
|Set on the colour setting screen in the Configuration menu.  Decimal code for the screen heading color
|Set on the colour setting screen in the Configuration menu.  Decimal code for the screen heading color
|-
|-
|ClockColour=-16777201  
|ClockDigitColour=4227327
|Set on the colour setting screen in the Configuration menu.  Decimal code for the figures on clock in top right corner of main screen
|-
|ClockColour=16777201  
|Set on the colour setting screen in the Configuration menu.  Decimal code for the main screen clock background color
|Set on the colour setting screen in the Configuration menu.  Decimal code for the main screen clock background color
|-
|TwelveHourClock=0
|Set by left click on clock on main screen
*0 = 24Hr clock mode
*1 - 12 Hr am/pm clock mode
|-
|-
|DisplaySolarData=0  
|DisplaySolarData=0  
Line 793: Line 801:
*0 = Disabled (default)
*0 = Disabled (default)
*1 = Enabled, adds an extra panel to the main screen below the recent extremes panel - EITHER
*1 = Enabled, adds an extra panel to the main screen below the recent extremes panel - EITHER
**Panel displays ''Temperature'', ''Dew point'' and ''Humidity'' (this [[FAQ#How_does_Cumulus_deal_with_extra_sensors.3F|extra sensor data]],  can be populated from Oregon WMR-928 stations) OR
**Panel displays ''Temp'', ''Dew pt'' and ''Hum'' (this [[FAQ#How_does_Cumulus_deal_with_extra_sensors.3F|extra sensor data]],  can be populated from Oregon WMR-928 stations, see next 3 parameters) OR
**Panel displays ''Evapotranspiration (ET)'', ''Ultraviolet (UV)'' and ''Solar radiation'' if station '''Type''' is Vantage Pro and solar data is available
**Panel displays ''Evapotranspiration (ET)'', ''Ultraviolet (UV)'' and ''Solar radiation'' if station '''Type''' is Vantage Pro and solar data is available
|-
|DisplayCloudBase=0
|Set in the Display Configuration Screen General block.
*0 = Disabled, (default)
*1 = Enabled, the calculated cloud base is displayed on the main screen. The calculation is a simple one; 1000 feet for every 4.5 degrees Fahrenheit difference between the temperature and the dew point.
|-
|TwelveHourClock=0
|Set by left click on clock on main screen
*0 = 24Hr clock mode
*1 - 12 Hr am/pm clock mode
|-
|-
|WMR928Channel1Caption=Extra channel 1  
|WMR928Channel1Caption=Extra channel 1  
|Set in the Display Configuration Screen ''WMR928 extra channel captions'' block. Note that the extra channel data for WMR928 stations is only displayed on the main screen if ''Display solar/extra data'' is Set in the Display Configuration Screen General block. This parameter defines the caption to be used when Cumulus reads observations from the extra sensor.
|Set in the Display Configuration Screen ''WMR928 extra channel captions'' block. Note that the extra channel data for WMR928 stations is only displayed on the main screen if ''Display solar/extra data'' is Set in the Display Configuration Screen General block (see previous parameter). This parameter defines the caption to be used when Cumulus reads observations from the extra sensor.
|-
|-
|WMR928Channel2Caption=Extra channel 2  
|WMR928Channel2Caption=Extra channel 2  
|Set in the Display Configuration Screen ''WMR928 extra channel captions'' block. Note that the extra channel data for WMR928 stations is only displayed on the main screen if ''Display solar/extra data'' is Set in the Display Configuration Screen General block. This parameter defines the caption to be used when Cumulus reads observations from the extra sensor.
|See previous parameter.
|-
|-
|WMR928Channel3Caption=Extra channel 3  
|WMR928Channel3Caption=Extra channel 3  
|Set in the Display Configuration Screen ''WMR928 extra channel captions'' block. Note that the extra channel data for WMR928 stations is only displayed on the main screen if ''Display solar/extra data'' is Set in the Display Configuration Screen General block. This parameter defines the caption to be used when Cumulus reads observations from the extra sensor.
|See 'WMR928Channel1Caption=Extra channel 1' parameter
|-
|WindGaugeRange=50
|Set in the Display Configuration Screen General block. Value represents the default full scale deflection of the top of the 3 wind plots in the wind speed units you have selected. Default value is 50 in that unit.
|-
|-
|SnowUnitText=cm  
|SnowUnitText=cm  
|Set in the Display Configuration Screen General block. Snow measurement unit. Default is cm.  Can be any unit (or other text) you like, remember all snow depth observations must be entered as an integer (without any decimal part)!
|Set in the Display Configuration Screen General block. Snow measurement unit. Default is cm.  Can be any unit (or other text) you like, remember all snow depth observations must be entered as an integer (without any decimal part)!
|-
|DisplayCloudBase=0
|Set in the Display Configuration Screen General block.
*0 = Disabled, (default)
*1 = Enabled, the calculated cloud base is displayed on the main screen. The calculation is a simple one; 1000 feet for every 4.5 degrees Fahrenheit difference between the temperature and the dew point.
|-
|-
|DisplayHumidex=0  
|DisplayHumidex=0  
|Set in the Display Configuration Screen General block
|Set in the Display Configuration Screen General block
*0 = Disabled (default) [[Heat_index]] displayed on main screen. The heat index is calculated only if the actual temperature in the shade (not in direct sunlight) is above 27 °C (80 °F), so normal temperature shown here for cooler temperatures.
*0 = Disabled (default) [[Heat_index]] displayed on main screen. The heat index is calculated only if the actual temperature in the shade (not in direct sunlight) is above 27 °C (80 °F), so normal temperature shown here for cooler temperatures.
*1 = Enabled, calculated [[Humidex]] value to be displayed on the main screen instead of Heat Index. Note that Cumulus displays degrees C or F for Humidex, whereas strictly speaking it is unitless. This is for the convenience of those who use Fahrenheit but would still prefer to see Humidex displayed, where it might be confusing to show the unconverted value.
*1 = Enabled, calculated [[Humidex]] value to be displayed on the main screen instead of Heat Index. (Note that Cumulus displays degrees C or F for Humidex, whereas strictly speaking it is unitless. This is for the convenience of those who use Fahrenheit but would still prefer to see Humidex displayed, where it might be confusing to show the unconverted value.)
|-
|-
|LegendSymbolWidth=3
|LegendSymbolWidth=3
Line 832: Line 832:
|Set in the Display Configuration Screen Graph block. The width of the plot lines in the graph body
|Set in the Display Configuration Screen Graph block. The width of the plot lines in the graph body
|-
|-
|ClockDigitColour=4227327
|WindGaugeRange=50
|Set on the colour setting screen in the Configuration menu. Decimal code for the figures in top right corner of main screen
|Set in the Display Configuration Screen General block. Value represents the default full scale deflection of the top of the 3 wind plots in the wind speed units you have selected. Default value is 50 in that unit.
|-
|-
|WindGaugeArcColour=16773091
|WindGaugeArcColour=16773091
5,838

edits