5,838
edits
SaratogaWX (talk | contribs) m (→1099: changed download link) |
m (Text replacement - "Cumulus.ini" to "Cumulus.ini_(Cumulus_1)") |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 306: | Line 306: | ||
*Add "second order" multiplier for outdoor Temperature calibration | *Add "second order" multiplier for outdoor Temperature calibration | ||
This last change allows a value to be provided which is multiplied by the temperature reading squared, and the result added to the actual reading (the supplied value can be negative). To use this, add a line to [[Cumulus. | This last change allows a value to be provided which is multiplied by the temperature reading squared, and the result added to the actual reading (the supplied value can be negative). To use this, add a line to [[Cumulus.ini_(Cumulus_1)#Section:_Offsets]] (with Cumulus stopped): | ||
TempMult2=x.x | TempMult2=x.x | ||
In other words, this means that the logged reading can be (TempMult2 * temp²) + (TempMult * temp) + TempOffset | In other words, this means that the logged reading can be (TempMult2 * temp²) + (TempMult * temp) + TempOffset | ||
Line 318: | Line 318: | ||
*Option (in Display Settings) to set the saved graph images to have a transparent background | *Option (in Display Settings) to set the saved graph images to have a transparent background | ||
*Option to send indoor data to Weather Underground | *Option to send indoor data to Weather Underground | ||
You can download a copy [https://cumuluswiki. | You can download a copy [https://cumuluswiki.org/Downloads/CumulusSetup.exe here] | ||
== 1100 == | == 1100 == | ||
Line 325: | Line 325: | ||
Instromet asked me to stop using one of the functions ''(the 'regress logs' command)'' of the logger, as they said it caused problems. So I produced a version of Cumulus which doesn't use that function - it identifies itself as build 1100 in Help - About. | Instromet asked me to stop using one of the functions ''(the 'regress logs' command)'' of the logger, as they said it caused problems. So I produced a version of Cumulus which doesn't use that function - it identifies itself as build 1100 in Help - About. | ||
If you are an Instromet user, and your logger operates at 115200 baud, you should use build 1100. | If you are an Instromet user, and your logger operates at 115200 baud, you should use build 1100. | ||
You can download a copy [ | You can download a copy [https://cumuluswiki.org/Downloads/CumulusSetup1100.zip here] | ||
== 1101 == | == 1101 == | ||
Line 331: | Line 331: | ||
If you are an Instromet user, and your logger operates at 19200 baud, you should use build 1101. | If you are an Instromet user, and your logger operates at 19200 baud, you should use build 1101. | ||
You can download a copy [ | You can download a copy [https://cumuluswiki.org/Downloads/CumulusSetup1100.zip here] |
edits