Version 1.9.4: Difference between revisions

From Cumulus Wiki
Jump to navigationJump to search
675 bytes added ,  16:28, 22 March 2021
m
Text replacement - "Cumulus.ini" to "Cumulus.ini_(Cumulus_1)"
m (Text replacement - "Cumulus.ini" to "Cumulus.ini_(Cumulus_1)")
 
(9 intermediate revisions by 3 users not shown)
Line 1: Line 1:
<big>Release Date: 27 October 2013 (build 1085)</big><br />
<big>Release Date: 27 October 2013 (build 1085)</big><br />
Latest Patch Update: 7 August 2014 (build 1098)<br />
Latest (general) Patch Update: 28 November 2014 (build 1099)<br />
If you are intending to upgrade to this release, please read all of the release notes since the build you are currently running.
If you are intending to upgrade to this release, please read all of the release notes since the build you are currently running.
<br /><br />
<br /><br />
Line 252: Line 252:
== 1093 ==
== 1093 ==


[http://sandaysoft.com/forum/viewtopic.php?f=2&t=10777 Full release Details]
[https://cumulus.hosiene.co.uk/viewtopic.php?f=2&t=10777 Full release Details]
*option to encode web pages using UTF-8.
*option to encode web pages using UTF-8.
*if you use standard Cumulus pages, you need to download the new ones that are HTML 5 compliant, and specify a UTF-8 encoded charset.
*if you use standard Cumulus pages, you need to download the new ones that are HTML 5 compliant, and specify a UTF-8 encoded charset.
Line 306: Line 306:
*Add "second order" multiplier for outdoor Temperature calibration
*Add "second order" multiplier for outdoor Temperature calibration


This last change allows a value to be provided which is multiplied by the temperature reading squared, and the result added to the actual reading (the supplied value can be negative). To use this, add a line to [[Cumulus.ini#Section:_Offsets]] (with Cumulus stopped):
This last change allows a value to be provided which is multiplied by the temperature reading squared, and the result added to the actual reading (the supplied value can be negative). To use this, add a line to [[Cumulus.ini_(Cumulus_1)#Section:_Offsets]] (with Cumulus stopped):
     TempMult2=x.x
     TempMult2=x.x
In other words, this means that the logged reading can be (TempMult2 * temp&sup2;) + (TempMult * temp) + TempOffset
In other words, this means that the logged reading can be (TempMult2 * temp&sup2;) + (TempMult * temp) + TempOffset
Line 313: Line 313:


== 1099 ==
== 1099 ==
This is the stable release of Cumulus 1 preceding the development of Cumulus 3 (MX).
*Save month.ini and year.ini when longest wet/dry spell occurs (so the record can't get lost if Cumulus is closed 'untidily')
*Save month.ini and year.ini when longest wet/dry spell occurs (so the record can't get lost if Cumulus is closed 'untidily')
*Log latest reading to diags when Fine Offset sensor contact lost (for diagnostic purposes)
*Log latest reading to diags when Fine Offset sensor contact lost (for diagnostic purposes)
*Option (in Display Settings) to set the saved graph images to have a transparent background
*Option (in Display Settings) to set the saved graph images to have a transparent background
*Option to send indoor data to Weather Underground
*Option to send indoor data to Weather Underground
*Change for reading from ''Instromet'' weather stations - Instromet asked me to change my code to avoid the use of part of the protocol (even though I was using it correctly) as it was causing some logger problems (a side effect is that 'rewinding' to a previous point is no longer possible)
You can download a copy [https://cumuluswiki.org/Downloads/CumulusSetup.exe here]
 
== 1100 ==
This build is a special one for Instromet station users only.
 
Instromet asked me to stop using one of the functions ''(the 'regress logs' command)'' of the logger, as they said it caused problems. So I produced a version of Cumulus which doesn't use that function - it identifies itself as build 1100 in Help - About.
If you are an Instromet user, and your logger operates at 115200 baud, you should use build 1100.
You can download a copy [https://cumuluswiki.org/Downloads/CumulusSetup1100.zip here]
 
== 1101 ==
This build is a special one for Instromet station users only.
 
If you are an Instromet user, and your logger operates at 19200 baud, you should use build 1101.
You can download a copy [https://cumuluswiki.org/Downloads/CumulusSetup1100.zip here]
5,838

edits

Navigation menu