1,648
edits
Line 88: | Line 88: | ||
**GW1000A (for 868 MHz sensors) | **GW1000A (for 868 MHz sensors) | ||
**GW1000B (for 915 MHz sensors) | **GW1000B (for 915 MHz sensors) | ||
**GW2000 (be aware for the frequency versions) | |||
*Misol GW1K gateway [http://www.misolie.net/misol-smarthub-wifi-gateway-with-temperature-humidity-pressure-gw1000-p-608.html SmartHub WiFi Gateway] | *Misol GW1K gateway [http://www.misolie.net/misol-smarthub-wifi-gateway-with-temperature-humidity-pressure-gw1000-p-608.html SmartHub WiFi Gateway] | ||
*Froggit DP1500 WiFi gateway [https://www.froggit.de/product_info.php?language=en&info=p410_dp1500-wi-fi-wetterserver-usb-dongle.html product_info_dp1500-wi-fi-wetterserver-usb-dongle] | *Froggit DP1500 WiFi gateway [https://www.froggit.de/product_info.php?language=en&info=p410_dp1500-wi-fi-wetterserver-usb-dongle.html product_info_dp1500-wi-fi-wetterserver-usb-dongle] | ||
Line 93: | Line 94: | ||
It is possible that model names may vary, which is why you should check at [https://www.wxforum.net/index.php?topic=40730.0 the wxforum.net forum]. | It is possible that model names may vary, which is why you should check at [https://www.wxforum.net/index.php?topic=40730.0 the wxforum.net forum]. | ||
CumulusMX can use these devices as main station or as extra sensor device. When used as main station, although there is no logger, if the user has the device send all data to Ecowitt.net server, CMX is able to retrieve those data as if it were a logger. So effectively CMX can be off-line without loss of data. | |||
To summarize ecowitt station types: | |||
Ecowitt Local API | |||
- prefer this if your device has the local api (most gateways GW1x00, GW2000 and some WNxxxx consoles) | |||
- in this mode CMX actively requsts data from the device | |||
- best accuracy, shortest polling interval | |||
HTTP Ecowitt | |||
- use this with devices that do not have the local api (most consoles, HPxxxx) | |||
- in this mode you must configure custom weather service upload to console | |||
- in this mode CMX only listens if any station would upload data to it | |||
- data update interval dependant on console custom service upload interval setting | |||
Ecowitt Cloud | |||
- use this only if your station does not have neither of local api or custom server upload (eg. 4g cellular station) | |||
- usable also if your station is on a different location than your CMX install | |||
- in this mode CMX downloads data from ecowitt.net without communicating to your station at all | |||
There is a [https://www.wxforum.net/index.php?topic=40730.0 comprehensive list of Ecowitt devices] and their features on WXForum, but you must register to see the featuresheets that are saved as pictures. | |||
See also the [[Webtags|Webtag List]] for using the values of the devices. | |||