Cumulusutils.ini: Difference between revisions

From Cumulus Wiki
Jump to navigationJump to search
261 bytes removed ,  20:14, 26 November 2022
m
(3 intermediate revisions by the same user not shown)
Line 287: Line 287:


=== [ExtraSensors] ===
=== [ExtraSensors] ===
ExtraSensors=false                       => If false the module is skipped, no menu entry will be made
ExtraSensors=false<br/>
ParticipatesSensorCommunity=false       => If false, the menu option ''SC map'' will not be generated
ParticipatesSensorCommunity=false<br/>
CleanupExtraSensorslog=false             => If true will remove old logfiles and keep only the current and the previous month
CleanupExtraSensorslog=false<br/>
UserModificationExtraSensorCharts=false => If true the ''Extra Sensor'' charts will not be overwritten in ''CutilsCharts.def'' and give the user the possibility to create his own charts
UserModificationExtraSensorCharts=false<br/>
LightningSensor=false                   => '''[Valid from version 7 and up]'''
LightningSensor=false<br/>
                                            If true the Ecowitt Lightning sensor is present and will be presented in the module.
ExternalExtraSensors=<br/>
                                            (NOTE that this sensor is not logged by CMX and therefore does not have a corresponding chart)
ExternalExtraSensors=                   => A comma separated list of strings naming the External Extra Sensors the user wishes to use (See [[External Extra Sensors]])


The list of parameters below defines which extra sensors are used in your system (combine with strings.txt for the descriptions (Captions) used). Fill with comma separated integer representing the extra sensor:
ExtraTemp=<br/>
ExtraHum=<br/>
ExtraDP=<br/>
SoilTemperature=<br/>
SoilMoisture=<br/>
AirQuality=<br/>
UserTemp=<br/>
LeafTemp=<br/>
LeafWetness=<br/>


'''NOTE:''' <br/>
'''NOTE:''' <br/>
''DoneToday'' is not configurable but is set/read by the application. Any value you put here will be modified. If the date is today then the corresponding action will not be carried out. You can force the action by emptying this parameter.
#''DoneToday'' is not configurable but is set/read by the application. Any value you put here will be modified. If the date is today then the corresponding action will not be carried out. You can force the action by emptying this parameter.
#the Ecowitt CO2 sensor is not parameterised but its presence is detected by the presence of a value in the database.
#the Ecowitt AirQuality sensors have an implicit accompanying AirQualityAvg giving the 24 hr average
 




[[Category:CumulusUtils]]
[[Category:CumulusUtils]]

Navigation menu