Extra Sensors: Difference between revisions

m
 
(6 intermediate revisions by the same user not shown)
''Extra Sensors'' is a feature already present in Cumulus 1. Ignored for long time by CumulusUtils, with the rise of the [https://www.ecowitt.com/shop/homePage Ecowitt ecology] and the support of CumulusMX for the GW1000 (and higher) devices, it has been decided to make ''Extra Sensors'' a standard module of CumulusUtils.
 
For the obvious reason of the absence of a log, the lightning sensor will be ignored by CumulusUtils as are additional sensors which can not be logged. (likeYou e.g.are LeafTemp3advised andto 4).use the [[Custom Logs|CustomLogs]] to chart Lightning.
''Extra Sensors'' have a certain complexity because, although handled by CumulusMX, they are kind of anarchic: unregulated, CumulusMX does not care, when detected they are always displayed only logged when logging is switched on and then not all of them are logged. There are more webtags than logged sensors etc... This complexity made some additional handling necessary.
 
For the obvious reason of the absence of a log, the lightning sensor will be ignored by CumulusUtils as are additional sensors which can not be logged (like e.g. LeafTemp3 and 4).
 
Please read the paragraph operation carefully and report any difficulty in operating the module both in this Wiki, from within the website or otherwise. I think all cases are covered but you never know.
 
For External Extra Sensors i.e. sensors the user has available outside the CMX system such as e.g. a Geiger Counter see: [[External Extra Sensors]].
 
In CMX version 3.22.0 - b3211 the Custom Logs were introduced, providing the possibility for the user to create their own logfiles for any value - also strings - which CMX produces in a [[Webtags|webtag]]. This called for a procedure in CumulusUtils to handle those logs. In version 6.21.0 this was realised. the [[Custom Logs]] procedure us based on the External Sensors module and has its own wiki page.
 
=== Dependency ===
UserModificationExtraSensorCharts=true
the charts will no longer be overwritten and the user may modify the generated charts to his own tasting.
 
=== Translation/Language ===
The translation of of this module is accommodated via two sections in the ''CUstringsXX.ini'' file: ''Compiler'' (most) and ''ExtraSensors'' (some).
 
You will find all translation tags for the sensor names in the section ''Compiler'' and this includes the three values for the lightning detector although those are not really explicit sensors. This is analogue to all standard plot variables.
 
The translation tags content for the extra sensor names are defaulted with the extra sensor description texts from ''strings.ini'' when the tags are created in the CUstringsXX.ini and can then be changed by the user. These modifications will be used in subsequent runs for the ''ExtraSensors'' module. As a consequence, the user may choose different descriptions in CMX and in CUtils for the ''Extra Sensors''.
 
To set back the default values of the tag names - the values in ''strings.ini'' - just remove the tags from the ''CUstringsXX.ini'' file.
 
== Operation ==
#After the first run the following inifile parameters exist (see below): ''ExtraTemp, ExtraHum, ExtraDP, SoilTemp, SoilMoisture, AirQuality, UserTemp, LeafTemp, LeafWetness''. Filling these with e.g. '''1,2,3''' activates those sensors and a subsequent run will show these under the menu choice ''Extra''.
#For the CO2 sensor the parameter ''CO2='', a value 0 (or empty ) or 1 (de-)activates that sensor which subsequently is handled as an extra sensor and will be shown under the menu choice ''Extra''.
#For the lightning sensor the parameter ''LightningSensor=true/false'' (de-)activates that sensor which subsequently is displayed as a normal Extra Sensor in the list. The Lichting sensor is currently not charted as it is not logged in the ExtraSensors log. Currently charting the Lightning sensor can only be done as an External Extra Sensor. Complete charting will be possible with the implementation ofUse the [[Custom Logs|CustomLogs (no dateand hasits beenmodule]] setfor yet)this.
#Finally, to make it work and to bring system in the ''Extra Sensors'', '''it is required''' for the user to use ''strings.ini'' (copy it from samplestrings.ini in the distribution of CumulusMX) in the CumulusMX directory and give the sensors you want to be handled by CumulusUtils '''a short meaningfull name'''.