5,838
edits
m (Corrected "CalculatedWC=1" text, see https://cumulus.hosiene.co.uk/viewtopic.php?p=164244#p164244) |
|||
Line 4,808: | Line 4,808: | ||
* Tick (value shown as 1 in Cumulus.ini) then Cumulus will calculate wind chill from temperature and wind speed | * Tick (value shown as 1 in Cumulus.ini) then Cumulus will calculate wind chill from temperature and wind speed | ||
** Note that there is a maximum temperature, and minimum wind speed, for Cumulus to make the calculation, see [[Wind_chill]] page | ** Note that there is a maximum temperature, and minimum wind speed, for Cumulus to make the calculation, see [[Wind_chill]] page | ||
* Don't tick (value shown as 0 in Cumulus.ini) action depends on | * Don't tick (value shown as 0 in Cumulus.ini) action depends on other items: | ||
** If Cumulus has non-default multiplier and/or offset settings for temperature or wind speed, Cumulus will calculate wind chill | ** If Cumulus has non-default multiplier and/or offset settings for temperature or wind speed, Cumulus will calculate wind chill | ||
** If station provides wind chill, then that will be used provided no multiplier/offsets have been specified for temperature or wind speed | ** If station does NOT make a wind chill value available to Cumulus, Cumulus MX reports an error if you have not ticked this setting, (that is different to how the setting worked with the legacy software). | ||
** If station provides wind chill, then that value will be used provided no multiplier/offsets have been specified for temperature or wind speed. | |||
|- | |- | ||
| ChillHourSeasonStart= | | ChillHourSeasonStart= |
edits